41 1815 d 4 h mjames /branches/stm32f103/ Updated for 72MHz timers. Triggered temperature sample 2mS after CB opens.  
40 1820 d 4 h mjames /branches/stm32f103/ Corrected prescaler values - RPM was reading 2x correct value .
Altered SPI speed for temperature sensors.
 
39 1822 d 5 h mjames /branches/stm32f103/ Updated to auto calibrate ADC, and use on-chip thermometer.  
38 1822 d 12 h mjames /branches/stm32f103/ Builds for STM32F103 blue pill.  
37 1825 d 0 h mjames /branches/stm32f103/ Changed to use STM32F103 Blue Pill instead of Nucleo board as these are now expensive.  
36 1825 d 3 h mjames /branches/ Changed name of branch because it has inconsistent case  
35 1825 d 3 h mjames /branches/stm32F103/ Making a branch to change to using Blue Pill from Nucleo board.  
34 1825 d 3 h mjames /trunk/Src/ Updated the minimum ignition pulse to 2.5mS  
33 2004 d 11 h mjames /trunk/ Removed redundant libraries  
32 2005 d 0 h mjames /trunk/ Updated  
31 2061 d 4 h mjames /trunk/ Altered to read SPI temperature sensors after ignition pulse goes low.  
30 2061 d 6 h mjames /trunk/ Removed wrap-around error in calculation of RPM (needed short int for modulo maths)  
29 2061 d 8 h mjames /trunk/ Fixed timer 3 as a trigger for the ADC  
28 2074 d 4 h mjames /trunk/ Updated to use the new libSerial - which doesnt reset the PLX timeout flag.  
27 2502 d 5 h mjames /trunk/Src/ Modified calibration of MAP sensor after using proper pressure gauge  
26 2802 d 5 h mjames /trunk/Src/ Added sensing of ignition pulses to reading CHT to avoid measuring just after rising efdge of ignition pulse.  
25 3096 d 5 h mjames /trunk/Src/ Enabled second CHT sender  
24 3096 d 7 h mjames /trunk/Src/ Changed MAP calibration.  
23 3354 d 3 h mjames /trunk/Src/ Changed CHT filter algorithm  
22 3376 d 4 h mjames /trunk/ Changed timeouts on ignition-on wire to 1 second as filtering sometimes seems to fail
Deleted 1023 reading CHT samples that happen from time to time.
 